Some DIY boards take a detachable camera module which can end up physically mounted either way up. Two Waveshare S3 Touch LCD 2 units with the same OV5640 module have been seen producing opposite image orientations, so no build-time default suits both and the sensor model cannot be used to tell them apart at runtime (see discussion in PR 331). Add a 'Rotate Camera' entry to the display settings menu on camera boards other than the official Jade units. The setting is persisted as a bit in the existing gui flags storage field and picks between the two already-compiled copy functions at runtime in the camera task, composing with any flipped display orientation. While the rotation is active the menu label reads 'Camera Rotated', doubling as the state indicator.
Collaborator
|
Merged to master, thanks! |
Contributor
|
Tested on my Waveshare S3 Touch LCD 2-C with the OV5640. Default preview is upside down, "Rotate Camera" fixes it and it stays after a reboot. QR scan works too. Thanks @cateim! |
cateim
added a commit
to self-labs/.github
that referenced
this pull request
Oct 2, 2026
Brings the profile from 2026-08-24 up to date: twenty pull requests accepted across nine repositories owned by eight people, the two merged into arendst/Tasmota, and a new "Open, and meant to be used" section for Tasmota IR, Tasmota for KinCony, Custom Branding, cups, ai-usagebar-win and DIY. Atlas Logistics leaves the production table: it is parked, and the profile itself promises that what is parked says it is parked. Radar de Promo and the PMES rosters enter it, and ALFERES gets its real numbers. The upstream badge reads 20 only after self-labs/self-labs counts Blockstream/Jade#335 and its stats job runs again. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
cateim
added a commit
to self-labs/self-labs
that referenced
this pull request
Oct 3, 2026
Blockstream applied the camera rotation change on their internal branch and closed the pull request without merging, as they did with the other four, and commit 9c097297 is in their master. Without an entry in ACEITOS_SEM_MERGE the search for is:merged never finds it, so the proof bar and the profile badges read 19 instead of 20. The comment above the list now says to confirm the commit landed before adding a PR there, since closed without merge is also what a rejected PR looks like. stats.json regenerated with an authenticated run: 20 PRs, 1785 commits, 37 repositories. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Description
Adds a persisted user setting to rotate the camera preview image 180 degrees, for boards whose camera module can be physically mounted either way up. This supersedes #331, which flipped the build-time default for the Waveshare S3 Touch LCD 2.
Root Cause / Context
CAMERA_OV5640over I2C, so a runtime check oncamera_info->modelcannot tell the units apart. The difference is physical: the module hangs on an FPC cable and fits either way up.Camera Orientationmenu isvisible if HAS_CAMERA && BOARD_TYPE_CUSTOM, so on a named board the symbol has no visible prompt and always falls back to its default. Whichever default wins, the other half of the builders cannot correct it.fb->buf), not the rotated copy, so orientation never affects scanning.Changes
main/storage.hGUI_FLAGS_CAMERA_ROTATEDas a bit in the existingGUI_FLAGS_FIELDbyte, as requested in diy: fix upside down camera image on Waveshare Touch LCD 2 #331.main/button_events.hBTN_SETTINGS_DISPLAY_CAMERA_ROTATEevent id.main/ui/dashboard.cmain/process/dashboard.cmain/camera.ccopy_camera_image_0andcopy_camera_image_180are both already built in this configuration and the copy function was already a runtime pointer.Testing
Waveshare S3 Touch LCD 2 with an OV5640 module, firmware
1.0.41-67:Official Jade units are excluded from the menu entry, and boards without a camera never compile it.
Motivation
Lets each builder correct the camera orientation once from the device menu, with the choice surviving reboots and firmware updates, instead of flipping a build default that regresses the other half of the units.
cc @bota87